Leak Detection System - Industrial Air Leak Testers
Testing Methodology:
Wet leak Test by using pressurized air
Testing Process:
- Machine works auto function- Loading Component Manually in the fixture
- Inlet air Pressure Monitor with the reference time(Seconds)
- Air bubbles by Visual Inspection
- HMI used to monitor the Inlet pressure and test time to identify the part OK NOT OK
Testing Methodology:
Air Leak test by using pressurized air
Leak Test Machine Working
- We will maintain the pressure by using Pressure sensor to maintain the given
pressure-Auto
- HMI used to monitor the Inlet pressure and test time to identify the part OK NOT
OK
Leak Tester in Chennai
Leak Detection System - Industrial Air Leak Testers